PDMS COMMANDS: MOSTLY STRUCTRUAL
NEW STRU COPY $V1
|
COPIES STRU FROM 1 SITE TO ANOTHER
|
Q USERM
|
GIVES CREATORS NAME
|
Q PPLIN TOS START WRT/DATUM
|
GIVES TOP OF STEEL OF UB/UC
|
Q IDP @ WRT /DATUM
|
GIVES THE COORD OF A POINT
|
Q ADEG (DRAFT)
|
GIVES THE C/VIEW ANGLE (ie 90 DEG)
|
Q ANGLE (HVAC)
|
GIVES THE CE ANGLE
|
Q ATEX (DRAFT)
|
GIVES THE SLAB TEXT ATTRIBUTES
|
Q ATT
|
GIVES THE CE ATTRIBUTES
|
Q BANG
|
GIVES THE CE BETA ANGLE
|
Q BORE (PIPING)
|
GIVES THE PIPE INSIDE DIA.
|
Q BSRF (DRAFT)
|
GIVES THE ATTACHED DRG/SHT (DRWG LEVL)
|
Q BTEX (DRAFT)
|
GIVES THE TEXT/GLAB ATTRIBUTES
|
Q CHEI (DRAFT)
|
GIVES THE CHARACTER HEIGHT
|
Q CLL (PIPING)
|
GIVES THE PIPE BRANCH LENGTH
|
Q
|
GIVES THE ATTRIBUTED COLOUR (YELLOW)
|
Q
|
GIVES THE CURRENT ACTIVE COLOUR
|
Q
|
GIVES THE CURRENT AID LINE COLOUR
|
Q
|
GIVES THE CURRENT ATTRIBUTED COLOUR
|
Q
|
GIVES THE CURRENT VISIBLE COLOUR
|
Q CREF
|
GIVES THE CONNECTION REFERENCE
|
Q CUTL
|
GIVES THE CE CUT LENGTH
|
Q DDNAME (DRAFT)
|
GIVES THE DIMENSION OWNERS NAME
|
Q DER LEN
|
GIVES THE CE EXACT LENGTH
|
Q DESC
|
GIVES THE CE DESCRIPTION
|
Q DESP
|
GIVES THE CE PARAMETERS
|
Q DIR (DRAFT)
|
GIVES THE C/VIEW ANGLE (ie N)
|
Q DISPLAY
|
GIVES THE TOLERANCE & REPRES LEVELS
|
Q DMTXT (DRAFT)
|
GIVES THE DIM TEXT ATTRIBUTES
|
Q DNST
|
GIVES THE CE DENSITY
|
Q DPOS (DRAFT)
|
GIVES THE LDIM POSITION ON SHEET
|
Q DRNE
|
GIVES THE END CUT-PLANE DIRECTION
|
Q DRNS
|
GIVES THE START CUT-PLANE DIRECTION
|
Q DTER (DRAFT)
|
GIVES THE LAYER/LDIM TERM'TR DEFAULT
|
Q E
|
GIVES THE CE EAST CO-ORDINATE
|
Q ELEM
|
GIVES THE CE ELEMENT NAME
|
Q FPT (DRAFT)
|
GIVES THE STRA FROM POINT CO-ORDS
|
Q FRAD
|
GIVES THE PLOO/PAVE RADIU ie 100mm
GIVES THE NEXTR/VERT RADIUS ie 100mm |
Q FUNC
|
GIVES THE CE FUNCTION
|
Q GCOF
|
GIVES THE CE GROSS C OF G
|
Q GTYP
|
GIVES THE GENERIC TYPE i.e. OD, HP, TG
|
Q GWEI
|
GIVES THE CE GROSS WEIGHT
|
Q H (PIPE SUPPT)
|
GIVES THE CE HANDER HEAD CO-ORDS
|
Q HEI
|
GIVES THE CE (PLOO LVL) PLT THK
|
Q HPOS (PIPING)
|
GIVES THE CE PIPE HEAD CO-ORDINATES
|
Q HT (PIPE SUPT)
|
GIVES THE CE HANDER TAIL CO-ORDS
|
Q IDP @ WRT /*
|
GIVES THE CE P POINT CO-ORDINATES
|
Q IDPL @
|
GIVES THE PLINE NAME USING CURSOR
|
Q INREF
|
GIVES THE CE IN REFERENCE
|
Q ISPEC (PIPING)
|
GIVES THE CE (PIPE) INSULATION
|
Q ITLE
|
GIVES LENGTH OF IMPLIED TUBE
|
Q JLIN
|
GIVES THE CE JOINT LINE
|
Q JUSL
|
GIVES THE CE JUSTIFICATION LINE
|
Q LASTMOD
|
GIVES THE DAT STRU WAS LAST MODIFIED
|
Q LEN (DRAFT)
|
GIVES THE STRA LENGTH
|
Q LEV
|
GIVES THE CE LEVEL (OBSTRUCTION ETC)
|
Q LHEI (DRAFT)
|
GIVES THE TEST LETTER HEIGHT
|
Q LIST
|
GIVES THE CE FITTINGS (NEG EXTR. ETC)
|
Q LOCK
|
GIVES THE LOCK STATUS
|
Q LSHAPE (DRAFT)
|
GIVES THE LABEL LEADER LINE STATUS
|
Q MATREF
|
GIVES THE CE MATERIAL REF
|
Q MCOUNT
|
GIVES THE NOS OF SUB MEMBERS IN CE
|
Q MCOUNT SCTN
|
GIVES THE NOS OF SCTN MEMBERS IN CE
|
Q MDB
|
GIVES THE PROJECT DATABASE
|
Q MEM
|
GIVES THE CE MEMBERS
|
Q MEML
|
GIVES THE CE MEMBER LINE
|
Q MIDP
|
GIVES THE CE MIDPOINT CO-ORDINATES
|
Q MPT (DRAFT)
|
GIVES THE STRA MID POINT CO-ORDS
|
Q MTLE
|
GIVES LENGTH OF MATERIAL TUBE
|
Q MTLL
|
GIVES CL LENGTH OF MATERIAL TUBE
|
Q MTO
|
GIVES THE CE MTO STATUS
|
Q
|
GIVES THE CE NAME
|
Q NCOF
|
GIVES THE CE NET C OF G
|
Q NSRF
|
GIVES THE CE NET SURFACE
|
Q NVOL
|
GIVES THE CE NET VOLUME
|
Q NWEI
|
GIVES THE CE NET WEIGHT
|
Q OBS
|
GIVES THE CE OBSTRUCTION LEVEL
|
Q ORI
|
GIVES THE CE ORIENTATION (SLOPE)
|
Q OSRF
|
GIVES THE SHEET OVERLAY (VIEW ONLY)
|
Q OWN
|
GIVES THE CE OWNER
|
Q PA (PIPING)
|
GIVES TE C ARRIVE CO-ORDINATES
|
Q
|
GIVES THE CE PARAMETERS ie SERIAL SIZES
|
Q PH (PIPING)
|
GIVES THE CE PIPE HEAD ATTRIBUTES
|
Q PH BORE (PIPING)
|
GIVES THE CE (PIPE HEAD) BORE
|
Q PH OD (PIPING)
|
GIVES THE CE (PIPE HEAD) DIAMETER
|
Q PI WRT/* (PIPING)
|
GIVES THE CE (PIPE SUPPORT) LOCATION
|
Q PKEY (DRAFT)
|
GIVES THE DIM PLINE STATUS (ie TCTF)
|
GIVES THE CE HVAC LEAVE CO-ORDINATES
| |
Q PLNA
|
GIVES THE PLINE NAMES
|
Q PLTXT (DRAFT)
|
GIVES THE PROJ TEST ATTRIBUTES
|
Q POS
|
GIVES THE CE CO-ORDINATES (START)
|
Q POS FITT
|
GIVES THE C/FITT CO-ORDINATES (START)
|
Q POS IDPL @
|
GIVES THE PLINE CO-ORD AT CE START
|
Q POS IN $V1
|
GIVES THE CE DISTANCE TO VAR. $V1
|
Q POS PIN1 WRT/*
|
GIVES THE CE CO-ORDINATES OF PIN 1
|
Q POS PLRF (DRAFT)
|
GIVES TE CURRENT VSEC CO-ORDS
|
Q POS POPLI NA PROP 0.5
|
GIVES THE CENTRE CO-ORDINATE POSITIONS OF THE PLINE (PPLI) AT (0.5X DER LEN) ON THE N/A
|
Q POS PPL1 BOS WRT/*
|
GIVES THE BOS PLINE CO-ORDINATES
|
Q POS WRT TO ID@
|
GIVES THE DIST FROM CE TO START OF IDENTIFIED MEMBER
|
Q POS1 WRT/*
|
GIVES THE CE CO-ORDINATES OF PIN 1
|
Q POSE
|
GIVES THE CE END CO-ORDINATES
|
Q POSPPLI NA PROP 0.5
|
GIVES THE CENTRE CO-ORDINATE POSITIONS OF THE PLINE (PPLI) AT (0.5X DER LEN) ON THE N/A
|
Q POSS
|
GIVES THE CE START CO-ORDINATES
|
Q POSS POSE
|
GIVES THE CE BOTH END CO-ORDINATES
|
Q POST FITT
|
GIVES THE C/FITT CO-ORDINATES (START)
|
Q POST IN $V1
|
GIVES THE CE DISTANCE TO VAR.$V1
|
Q POST PLRF (DRAFT)
|
GIVES THE CURRENT VSEC CO-ORDS
|
Q PRLS
|
GIVES THE DESP NAME TYPES
|
Q PT (PIPING)
|
GIVES THE CE (PIPE TAIL) ATTRIBUTES
|
Q PT OD (PIPING)
|
GIVES THE CE (PIPE TAIL) DIAMETER
|
Q PURP
|
GIVES THE STRU PURPOSE ATTRIBUTE
|
Q RAD (HVAC)
|
GIVES THE CE RADIUS
|
Q RCOD (DRAFT)
|
GIVES THE VIEW ORIENTATION
|
Q REF
|
GIVES THE CE PDMS REFERENCE NO
|
Q REPRES
|
GIVES THE CE REPRESENTATION STATUS
|
Q RRSF (DRAFT)
|
GIVES THE CURRENT VIEW RULE SETTINGS
|
Q SIZE (DRAFT)
|
GIVES THE VIEW O/ALL DIMENSIONS
|
Q SJUS
|
GIVES THE PLOO JUSTIFICATION ie UTOP, DCEN, DBOT
|
Q SNAP (DRAFT)
|
GIVES THE SNAP SETTING (ON/OFF)
|
Q SPRE
|
GIVES THE CE SPECIFICATION REFERENCE
|
Q STEXT
|
GIVES THE ATT PENETRATION IDENT
|
Q TCTL OR (Q CUTL)
|
GIVES THE CE CUT LENGTH
|
Q THMRF (DRAFT)
|
GIVES THE CE (SYMBOL) NAME
|
Q THPOS (DRAFT)
|
GIVES THE C/VIEW MATCHLINE CO-ORDS
|
Q TPOS (PIPING)
|
GIVES THE CE PIPE TAIL CO-ORDS
|
Q TPT (DRAFT)
|
GIVES THE STRA TAIL POINT CO-ORDS
|
Q TULE
|
GIVES THE BRANCH TUBE LENGTH
|
Q TYPE
|
GIVES THE CE TYPE ie SCTN, PANE
|
Q USER
|
GIVES THE CE USER DATABASE
|
Q USERMOD
|
GIVES THE LAST USER LOGIN ID (STRU)
|
Q VLIMITS (DRAFT)
|
GIVES THE VIEW LIMITS
|
Q VOL CE
|
GIVES THE CE VOLUME
|
Q: DTYPE
|
GIVES THE FRMW STYLE TYPE (ie STLS)
|
Q: STATUS
|
GIVES THE CE STRU STATUS ie 'AFC'
|
Q:SWCODE
|
GIVES THE CE WEIGHT CODE
|
SEE ALSO:
No comments: