PDMS TIPS & TRICKS - Piping Info -->

Piping Info

Sharing The Piping Design Engineering Knowledge and job post

Search box

Wednesday, January 26, 2011

PDMS TIPS & TRICKS


PDMS TIPS & TRICKS

1.  If you want to invert the HEAD and Tail of a particular branch then select the branch and modify –> Hierarchy –> Reverse

2.     Normally in PDMS the precision set to 0 decimals. If you want to increase the Decimal points enter the following in the command prompt.
PREC 4 DP ( where 4 is the no. of decimal points)

3.     If you want to change only few values of a desparam you can use the following command
DESP n5 200 n8 500

This will change only the 5th and 8th parameter of a desparam

4.     If you are working in any modules (Equipment, Structures) and you want to use piping components creation form then use the following command in the PDMS command prompt.

Show _CDCOMP

5.     To Zoom in of the CE, type Auto CE.

6.     Put some items in the graphic view and use the following command
show !!gphmotion

(Auto rotation..Auto Zoom, Auto Whoble effects)

7.     Distance Measuring command
CONST DIST IDP@ TO IDP@ 
CONST DIST P0 TO P0 OF ID@ 
CONST DIST PA TO PA OF NEX


8.     Want help on your syntax (PDMS Commands) then type
show !!syntaxhelp

PIPING TRAINING COURSE, PDMS TRAINING, AVEVA PDMS TRAINING, PDMS TRAINING VIDEO, PDMS TUTORIAL VIDEO, PDMS SOFTWARE TRAINING,  PDMS SOFTWARE PIPING

2 comments:

  1. I have problem with clear command line in
    Socketweld connections.
    For buttweld connections clear length is equal to spool
    But in socketweld connections clear and spool have deferent length.

    ReplyDelete
  2. how to open create window with command

    ReplyDelete